  • HVAC Centralized Air Handler with Advanced Heat Recovery Fahu/Ahu
  • HVAC Centralized Air Handler with Advanced Heat Recovery Fahu/Ahu
  • HVAC Centralized Air Handler with Advanced Heat Recovery Fahu/Ahu
  • HVAC Centralized Air Handler with Advanced Heat Recovery Fahu/Ahu
  • HVAC Centralized Air Handler with Advanced Heat Recovery Fahu/Ahu
  • HVAC Centralized Air Handler with Advanced Heat Recovery Fahu/Ahu
Find Similar Products
  • Overview
  • Product Parameters
  • Product Description
  • Detailed Photos
  • Company Profile
  • Certifications
  • Our Advantages
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
2000-60000CFM
Type
Air Handling Unit
Air Tube Material
Galvanized Sheet
Corrosion Durability
Higher
Operating Voltage
380/400 VAC
Noise Level
Ultra Quiet
Application Fields
HVAC
Mounting
Floor Standing
Lifetime
5~10 years
Certification
ISO, CE, CCC, IAF
Condition
New
Shell Material
Galvanized Sheet Metal
Heat Exchanger Material
Copper
Fan
Galvanized Sheet Metal
Motor
Mainstream Brands
Water Pan
Integrated Molding
Transport Package
Wooden Box Packaging
Specification
1100x730x700-3700x2330x1750mm
Trademark
OULAIRUINA
Origin
Shandong
HS Code
8414599099
Production Capacity
100, 000 Units/Year

Product Description

 
 

Product Parameters

 
FAHU Heat Pump Heat Recovery
Model unit RNPH400W RNPH500W RNPH0600W RNPH0750W RNPH1000W RNPH1200W RNPH1500W RNPH1800W RNPH2400W RNPH3200W
cooling capacity Kw 40.8  46  57.9  80.8  97.7  120  156  189  240  320 
heating capacity Kw 41.4  47  58.5  82  99  121.7  166  195  246  329 
IPLV - 5.5  5.47  5.39  5.35  5.32  5.3  5.27  5.21  5.16  5.1 
Air supply volume CMH 4000-5000 5000-6000 6000-7000 7500-10000 10000-12000 12000-15000 15000-18000 18000-23000 24000-30000 32000-40000

Exhaust air volume
CMH 4000-5000 5000-6000 6000-7000 7500-10000 10000-12000 12000-15000 15000-18000 18000-23000 24000-30000 32000-40000

Humidification amount
Kg/h 19.3  22  27.3  38.2  46.1  56.6  73  89  113  148 
Heat recovery method - Air-cooled heat pump Air-cooled heat pump Air-cooled heat pump Air-cooled heat pump Air-cooled heat pump Air-cooled heat pump Air-cooled heat pump Air-cooled heat pump Air-cooled heat pump Air-cooled heat pump
power supply - 380V/3/50Hz 380V/3/50Hz 380V/3/50Hz 380V/3/50Hz 380V/3/50Hz 380V/3/50Hz 380V/3/50Hz 380V/3/50Hz 380V/3/50Hz 380V/3/50Hz
compressor type - Fully enclosed turbine type Fully enclosed turbine type Fully enclosed turbine type Fully enclosed turbine type Fully enclosed turbine type Fully enclosed turbine type Fully enclosed turbine type Fully enclosed turbine type Fully enclosed turbine type Fully enclosed turbine type
consume
power
COP
Refrigeration (standard/energy-saving operation) Kw 10.2/8.67 11.8/10.03 14.8/12.58 20.4/17.34 25/21.3 30.8/26.2 40/34 47/40 61.4/52.2 82.1/69.8
Heating (standard) Kw 8.49  9.6  12.2  17  20.7  25.4  34.6  40.5  51.5  68.6 
Refrigeration (standard/energy-saving operation) - 4.0/4.71 4/4.59 3.9/4.6 3.96/4.7 3.91/4.6 3.9/4.5 3.9/4.5 39.6/4.6 3.91/4.6 3.9/4.6
Heating (standard) - 4.9  4.9  4.8  4.82  4.78  4.73  4.8  4.82  4.78  4.8 
fan form - Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal
motor Output of air supply motor Kw 3.7  5.5  7.5  7.5  11  15  18.5  22  30 
Exhaust motor output Kw 3.7  5.5  7.5  7.5  11  15  18.5  22  30 
Total power consumption Kw 4.01  4.5  5.61  8.05  9.2  12.6  16.8  21.2  25.1  39.5 
structure External residual pressure Air supply side Pa 500  500  500  500  500  500  500  500  500  500 
Exhaust side Pa 500  500  500 500 500 500 500  500  500  500 
noise dB(A) 61  61  63  66  68  71  74  76  76  77 
weight Kw 1050 1250 1400 1950 2000 2400 2800  3850  3910  4000 
 

Product Description

HVAC Centralized Air Handler with Advanced Heat Recovery Fahu/AhuHVAC Centralized Air Handler with Advanced Heat Recovery Fahu/AhuHVAC Centralized Air Handler with Advanced Heat Recovery Fahu/Ahu

Detailed Photos

HVAC Centralized Air Handler with Advanced Heat Recovery Fahu/Ahu
 
 

Company Profile

HVAC Centralized Air Handler with Advanced Heat Recovery Fahu/Ahu

     
      Shandong Oulai Ruina Environmental Technology Co., Ltd, founded in 1996, boasts an impressive 23-year legacy of innovation and excellence. Within its expansive workshop spanning over 10,000 square meters, the company houses over 60 state-of-the-art processing equipment, backed by a robust investment exceeding 60 million yuan. This dynamic enterprise is a hub of comprehensive capabilities, seamlessly integrating research, design, production, sales, installation, and unparalleled service. 
Our premier product offerings include a diverse range of high-performance solutions: from heat recovery fresh air ventilators and fresh air total heat exchangers to silent exhaust fans and high-efficiency purification fans, both bidirectional and unidirectional. We also specialize in central self-balancing fresh air systems, fresh air purifiers, electrostatic precipitators, rotary heat recovery units, and advanced air treatment solutions.

Our fan coil units and dehumidification technologies are expertly crafted to meet the nuanced demands of sectors such as healthcare, science, education, medical care, finance, and modern office environments.


Our commitment to excellence is matched by our expansive service offerings, including comprehensive computer design, detailed drawing disassembly, OEM, and ODM services.

We are proud to have forged enduring partnerships with global market leaders like 3M and Haier Group.

Leading the charge in innovation, we've equipped our operations with cutting-edge production technologies, such as fully automatic fiber laser cutting machines, Y-shaped solid laser cutters, CNC turret punching, bending, and shearing machines, all benchmarked to international standards.

Our dedication to quality is underscored by our achievements in certifications, including ISO9001, ISO14001, and OHSAS18001. We have also earned national-level fresh air CCC certification, CRAA performance certification, a national industrial production license for air handling units, and numerous testing reports.

Our pioneering spirit is further evidenced by holding one invention patent, twelve utility model patents, and seven design patents, reinforcing our position at the forefront of industry innovation.

HVAC Centralized Air Handler with Advanced Heat Recovery Fahu/Ahu

Certifications

------   Authentication Certificate   ------

HVAC Centralized Air Handler with Advanced Heat Recovery Fahu/Ahu------   Patent certificate   ------

HVAC Centralized Air Handler with Advanced Heat Recovery Fahu/AhuHVAC Centralized Air Handler with Advanced Heat Recovery Fahu/Ahu

Our Advantages

We are a factory trade integrated foreign trade enterprise, and our advantages are:

1. Customized service capability: We can better meet the customized needs of our customers. Based on their specific requirements, we can provide personalized customization in product design, production technology, packaging, and other aspects, and provide customized products and solutions for our customers.

2. Accumulation of Quality Reputation: Strict quality control helps enterprises establish a good quality reputation, win the trust and reputation of customers in the market, and promote long-term development and market share expansion.

3. Fast delivery: We can flexibly adjust production plans and arrange production schedules according to order conditions and market demand to ensure timely delivery. For urgent orders or order changes, able to quickly coordinate production resources, make quick responses, and improve customer satisfaction.

4. Professional technical support: We have a professional production technology team that can provide customers with professional technical support and solutions during the product sales process, helping them solve problems encountered during product use and enhancing their trust and dependence on us.

5. After sales response: When customers encounter problems during use, our company's after-sales team can respond quickly, solve problems in a timely manner, and provide high-quality after-sales service.


 

HVAC Centralized Air Handler with Advanced Heat Recovery Fahu/Ahu

Packaging & Shipping

HVAC Centralized Air Handler with Advanced Heat Recovery Fahu/Ahu

FAQ

1Q: I cannot find the product in your catalog. Can you customize it for me?
1A: Sure, you can directly consult customer service.

2Q:Can you customize products and packaging?
2A: Yes, it is possible.

3Q:How can I obtain samples?
3A: We provide free samples of raw materials, and you only need to pay the lowest shipping cost.

4Q:How to ensure product quality?
4A: We have international authoritative certification.

5Q: I need a price list for all your products. Do you have a price list?
5A: Please send us your information and submit it.

6Q: Can we provide drawing design services?
6A: Yes, we have a professional ventilation system engineering team to design and optimize solutions for your project.

7Q: Do you have technical support?
7A: We have a professional technical team to reply to you.

8Q: Are the accompanying installation accessories available for sale?
8A: Yes, there are. Please consult customer service for attached products and quotations at any time

9Q: What is your delivery time?
9A: For standard products, it takes approximately 30-40 days.